X2 control 4

4'' HMI with iX runtime and CODESYS soft control

  • 480 × 272 pixel (16:9) TFT-LCD touch screen
  • 1.5 GB application memory
  • Ethernet 2x100 Mbit
  • EtherCAT as standard
  • CODESYS control integrated
  • CE, FCC, KCC, UL approvals
  • DNV GL, KR, LR, ABS, CCS, BV, NK, RS marine approvals
Contact Print (PDF)

Facts

General description

Part number 630001705
Life cycle status Active
Warranty 2 year

Certifications

General CE, FCC, KCC, UL 61010-2-201
Marine KR, LR, ABS, BV, CCS, NK, DNV GL, RS
Safety UL 61010-1, UL 61010-2-201, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-201

Mechanical

Mechanical size 145 x 104 x 50mm
Panel Mount, VESA 50 x 50
1million finger touch operations
Touch type Resistive
Cut-out size 130 x 89mm
Weight 0.5 kg
Housing material Powder-coated aluminum, Gray

Power

Input voltage 24 V DC (18 to 32 VDC)CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supplymust conformwith the requirements for class II power supplies.
Power consumption (max) 12W
Input fuse Internal DC fuse

Hardware platform X2
CPU i.MX6DualLite, Dual Cortex-A9 1.0GHz 512kBL2cache
RAM 1 GB
FLASH 2GB SSD(eMMC), 1.5GB free for application

Display

Size diagonal 4.3″ diagonal
Resolution 480x272 pixels
Backlight LED Backlight
Backlight life time 50000 hours
Backlight brightness 300 cd/m2
Backlight dimming Industrial Dimming
Display type TFT-LCD with LED backlight

Softcontrol

Codesys runtime version 3.5
Codesys EtherCAT Yes
Codesys Modbus Ethernet Yes
Codesys Modbus RTU Yes
CANopen Yes
Non volatile variables 32 KB

Serial communication

Number of serial ports 1 Port 9pin DSUB
Serial port 1 RS 232 (RTS/CTS)
Serial port 2 RS422/485
Serial port 3 RS485 (only if COM 2 is RS485)

Ethernet communication

Number of Ethernet ports 2
Ethernet port 1 1x10/100 Base-T (shielded RJ45)
Ethernet port 2 1x10/100 Base-T (shielded RJ45)

Communication CAN

Number of CAN ports 1
CAN port 1 0.5 MBit

Expansion interface

Expansion port Yes, ciX expansion module
SD card SD and SDHC
USB 1xUSB 2.0 500mA

Environmental

Operating temperature -10°C to +60°C
Storage temperature -20°C to +70°C
Shock 15g, half-sine, 11ms according to IEC60068-2-27
Vibration 1g, according to IEC 60068-2-6, Test Fc
Sealing front IP65, NEMA 4X/ 12 and UL 50E Type 4X/ 12
Sealing back IP20
Humidity 5% – 85% non-condensed

Resources

Drawings

File name Date
Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI 2022-10-05 14:15:53
CAB108 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel 2022-09-20 15:55:15
CAB111 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B operator panel 2022-09-20 15:58:34
CAB110 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel 2022-09-20 15:57:35
CAB105 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel 2022-10-10 08:36:51
CAB106 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel 2022-09-20 15:58:03
CAB107, 25-pol to 9-pol adapter, Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel 2022-09-20 15:57:58
CAB109 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel 2022-09-20 15:58:14
Cable CAB154: Cable for CANopen between X2 Control and BFI 2022-10-05 15:03:44
CAB153 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel 2022-10-10 08:38:06
CAB150 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel 2022-10-10 08:37:51
CAB104 Cable Drawing forX2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel 2022-10-10 08:36:52
CAB103 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C 2022-10-10 08:36:50
CAB101 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel 2022-10-10 08:36:49
CAB100 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel 2022-09-20 15:57:40

Program examples/Start-up

File name Date
Add Tags to Tagmonitor by script 2022-10-31 15:57:37
Program example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3. 2024-02-21 11:21:02
iX Templates for E-key and X-Key 2022-10-31 15:58:35
Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414 2023-04-19 08:44:17
Ping from IX x2 terminal 2022-10-31 15:58:33
G Series, GT-5112 Program example X2 Control and GN-9386 2022-10-10 16:53:40
G series, GT-5112 Program example X2 Control and GN-9289 2022-10-10 16:53:43
G Series, GT-5112 Program example X2 Control and GN-9273 2022-10-10 16:53:44
G series, X2 Control, Parameter Set of I/O Modules connected to GN-9289 or GN-9273 2022-10-10 16:53:46
G series, X2 Control, Example with GN-9386 (EtherCAT) 2022-12-28 12:57:26
G series, X2 Control, Example with GN-9289 2023-03-22 10:52:36
G series, X2 Control, Example with GN-9273 2022-10-10 16:53:22
Program example CANOpen X2 Control - GN-9261 - BCS-XP325 2022-09-22 15:50:47
X2 control StartUp Guide Basic Settings SUEN284 2022-09-22 15:42:30
Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405 2023-03-14 10:30:39
Quick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406 2023-03-14 10:30:59
Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403 2023-03-14 10:29:35
Quick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series, SUEN00402 2023-03-14 10:29:13
X2 control / X2 marine SC / X2 extreme SC / BoX2 pro SC / BoX2 extreme SC with CODESYS (all image versions) - Startup, recommendations and limitations (SUEN00392) 2024-07-02 07:58:02

Information document

File name Date
​Guidelines for TxA and TxB migration to X2. 2022-10-10 08:38:10

Drivers

File name Date
iX and Allen-Bradley Ethernet CLX 2022-09-21 12:36:46

Brochures

File name Date
X2 series (German) 2022-09-21 08:11:38
X2 brochure (Spanish)​ 2022-09-21 08:12:32
X2 brochure 2019 (French) 2024-01-15 10:52:15
X2 brochure (English), BREN631 2022-09-21 08:11:56

Smart Engineering Resources

File name
BFI-E3 by Modbus TCP V1.0.2
Detect Internet connection - iX script module
Serial comms FBs - CODESYS library
Execute external SQL queries from file
FTP Client - iX sample
iX user authentication
Vessel central dimming - iX sample
Recipes with pictures - iX sample
SoftMotion lite with X2 control - CODESYS library
Alarm & Monitoring extension
Detect USB or SD card - iX script module
Login dialog customized - iX script sample
Log custom debug messages - iX sample
Setting up projects for Energy Meter
Get NIC information - CODESYS library
BFI-P2/H3 by EtherCAT V2.0.0
TCP client and server - CODESYS library
OEE calculation example
MQTT Client - iX script module
Excel basic process data template
MQTT Client (JSON) - iX script module
Quadratic terms calculator - iX script module
NMEA 0183 listener - CODESYS library
Detect VNC Client - iX script module
X2 Clock sync from PLC - iX script module
Barcode scanner USB - iX script module V1.0.1
Fast logging - CODESYS library
DatePicker - iX Developer script
Serial ReadWrite - iX script module
BFI-P2/H3 by Modbus TCP V1.0.3
Barcode scanner serial - iX script module
Custom recipe - iX script module
iX CyberSecurity Extension V1.1.9
iX File browser
CSV read delimit - CODESYS library
Customise report - iX script module
Password expire - iX script module
BFI-P2/H3/E3 by Modbus RTU V2.0.0
Power BI basic process data template
Genset sample - iX template
MJPEG graphical control - iX application
Conveyor product tracking - CODESYS library
Multiple alarm handling - CODESYS library
Scheduler online editor - iX script module
X2 / BoX2 to GL9971 (PIO) sample
Limited availability

X2 control 4

4'' HMI with iX runtime and CODESYS soft control


EOL - End Of Life:
-

LTB - Last Time Buy:
-

LTD - Last Time Delivery:
-

LTR - Last Time Repair:
-

Replacement Parts: